1. SPECIFICATIONS

(1) Composition

1) X-ray generator (Model : SIG-102, Rev.0)

2) Collimator (Model : 31-BLD-C, Rev.0)

3) Power cord (Model : HI305-PC3, Rev.0) : more than 5 meter

4) Cord with hand switch (Model : HI305-ES4, Rev.0) :more than 3 meter

 

(2) Performance

1) Input power requirement

Voltage : 100 ~ 130Vac / 205 ~ 240Vac

Frequency : 50 / 60Hz

Phase : Single phase

2) Power Consumption : 2.8kVA

3) Generator : Inverter type

4) Enclosure leakage current : NC 0.1,  SFC 0.5

5) Limit of leakage radiation : 100mR/h

6) Output rating (See the TABLE 1)

7) Max. kV deviation : ? 5%

8) Max. mAs deviation : ? 10%

 

[TABLE 1]

kV range (2kV steps)

mAs range

 

40 ~ 48

0.4 ~ 50

 

50 ~ 58

0.4 ~ 40

 

60 ~ 68

0.4 ~ 40

 

70 ~ 78

0.4 ~ 40

 

80 ~ 88

0.4 ~ 40

 

90 ~ 100

0.4 ~ 40

 

(3) X-ray tube

MODEL

S9 (Stationary anode tube)

Max. tube voltage

110 kV

Min. tube voltage

50 kV

Max. filament current

3.1 A

Focal spot

1.2 mm

Target angle

16 degrees

Inherent filtration

At least 0.8mmAl equivalent at 50 kV

Anode heat storage capacity

14 kJ (20 kHU)

 

(4) Collimator

Irradiation Area Form

Square (Knob driving type)

Max. Irradiation Area

Within 35 ? 35 on SID 65

Min. Irradiation Area

Within 5 ? 5 on SID 100

Lighting Time

Automatic Lights Out within 30 seconds,

Halogen Lamp (12V/50W)

Average Illumination

100 Lux

Inherent filtration

0.7 mmAl

 

 

(5) Dimensions (unit : mm)

1) X-ray generator : 230(W) ? 310(D) ? 175(H)

2) Collimator      : 150(W) ? 82(D) ? 132(H)

           

 

(6) Weight (Gross weight : 11kg)

1) X-ray generator : 9kg

2) Collimator   : 2kg

 

(7) Environmental condition

 

Operation

Transport & Storage

Ambient temperature range

5 ~ 40

-20 ~ 70

Relative humidity range

20 % ~ 80 %

5 % ~ 90 %

Atmospheric pressure range

70 kPa ~ 106 kPa

50 kPa ~ 106 kPa

 

(8) The Composition of with the Unit

1) Main X-ray unit : 1

2) Light Beam Collimator : 1

3) Input Power Supply Cord : 1

4) Remote control Hand Switch with Cord : 1

5) Carrying Case : 1

6) Manual TW-102 (Manual for Operation and Service) : 1

 

 
Carryng case included

 

Optional mobile stand dimensions: